Digital Insutest
1000 / 2500 Digital
Insulation Testers with auto range selection is a real digital
Insulation resistance tester+ digital Multimeter. It has features of
complete functions, high accuracy, reliability in operation and
convenience in use Output test voltage can be switched among
250V/500V/1000V for Metrix, 1000
& 500V / 1000V / 2500V for Metrix, 2500 Metrix -1000 / 2500 can
monitor the output high voltage in real-time way. At any time, the user
can observe actual measurement voltage that is output by the meter,
effectively avoiding misjudgment caused due to output voltage and
conforming to the rated value. The measurement range of the meter can
reach up to 40G ohm. The measurement time can be set up according to
requirements. After a measurement is completed, the measured result can
be kept automatically. Functions of the digital multimeter include AC /
DC voltage, current, resistance, capacitance, frequency, diode, and ON
/ OFF measurement. The functions of the multimeter, you need not be
worried that you would suffer electric shock due to high voltage
generated by the insulating resistance tester. The product is
applicable to measurement of the insulating resistance f various
insulating materials and electric equipment's such as transformers,
motors, cables, switches and electric apparatuses. It is also
applicable to maintenance, test and inspection of various electric
equipment's. it is compact in structure, convenient to carry and an
ideal electrical and electronic testing meter of yours
- Accuracy: =%reading =number, one year warranty
- Environment to guarantee the accuracy 23°C=5°C, less than 75% RH
Rated measurement voltage, valid measurement range, and precision
Rated voltage
|
Measurement range
|
Accuracy
|
250V
|
0.25M-400MΩ |
|
500V
|
0.5MΩ-4GΩ |
0.2M-200MΩ=3%rdg=5 |
1000V
|
1.5M-40G
|
200M-4gΩ=5%RDG=5 |
2500V
|
5M-40GΩ |
4G-40GΩ=10%rdg=5 |
Display range
Rated voltage
|
Dispaly range (auto range)
|
Resolution
|
250V
|
4M/40M/400MΩ |
1K/10K/100KΩ |
500V
|
4M/40M/400M/4GΩ |
1K/10K/100K/1MΩ |
1000V
|
40M/400M/4G/40G
|
10K/100K/1M/100MΩ |
2500V
|
40M/400M/4G/40GΩ |
10K/100K/1M/100MΩ |
DC voltage (DCV)
Range
|
Accuracy
|
Resolution
|
400mV
|
=(0.5%+5b)
|
0.1mV
|
4V
|
1mV
|
40V
|
10mV
|
400V
|
100mV
|
1000V
|
=(0.8%+5b)
|
1V
|
- Input Impedance 400mV=1000MΩ, 10MΩ for other ranges
- Maximum input voltage DC or AC peak value 1000V
AC voltage (ACV)
Range
|
Accuracy
|
Resolution
|
4V
|
=(0.8%+5b)
|
1mV
|
40V
|
10mV
|
400V
|
100mV
|
700V
|
=(1%+5b)
|
1V
|
- Input Impedance 400mV=1000MΩ, 10MΩ for other ranges
-
Maximum input voltage DC or AC peak value 1000V
- Frequency range 40Hz-400Hz (400V and 700V range is 40Hz "100Hz)
- Maximum input voltage DC or AC peak value 100V
- Display: Average (sine wave virtual value calibration)
DC Current (DCA)
Range
|
Accuracy
|
Resolution
|
40mA
|
=(0.8%+5b)
|
10mA
|
400mA
|
100mA
|
Overload protection: 0.5A/250V fuse
AC current (ACA)
Range
|
Accuracy
|
Resolution
|
40mA
|
=(0.8%+5b) |
10mA
|
400mA
|
|
100mA
|
Overloard protection: 0.5A/250V fuse
|