Features
- Conforms to IEC 61010 CAT.II600V, CATIII 300V,
over voltage and double insulation standard
- Display 3.1/2 digits, LCD display maximum 1999
- Can measure small current 2A
- Auto polarity display
- Overload display "OL" or "-OL"
- Data Hold
- APO function to save battery power. II Low
battery indication
- Measurement speed 3 times / sec.//1 meter Drop
test passed
- Powe: 2 x 1.5V" AAA "battery// Size: 35mm x 64mm
x 185mm approx. 200g. battery included
- Jaws diameter Max. Ø 30mm suitable for 600A AC
also ensures easy clamping even for narrow conductors
- Accessories: Test Leads, Carrying case,
Instruction manuals 2 x 1.5V " AAA" Batteries included
- "K" type temperature probe included for 225 x L
- Storage Temperature and Humidity: -20oC
- 60oC (<-75%RH)
Specifications AC Current Auto Range
Range
|
Resolution
|
Accuracy
|
Frequency
Response
|
Overload
Protection
|
2.000A
|
0.001A
|
+-(4% + 20) <-0.4A
+-(3% + 12)
|
50Hz - 60Hz
|
600A rms
|
20.00A
|
0.01A
|
+-(3% + 12) <-4A
+-(2% + 8)
|
200.0A
|
0.1A
|
+-(1.5%
+ 5)
|
600A
|
1A
|
Remarks:
- Displays effective value of sine wave (mean value
response)
- To adjust reading in accordance with effective
value.
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
2.000V
|
1mV
|
+-(1.2% + 5)
|
600V rms
|
20.00V
|
10mV
|
200.0V
|
100mV
|
600V
|
1V
|
+-(1.5% + 5)
|
Remarks:
- Input impedance: 10MΩ//<100pF"
- Displays effective value of sine wave (mean value
response)
- Frequency response: 40Hz - 1kHz
- To adjust reading in accordance with effective
value
DC
Voltage Auto Range:
Range
|
Resolution
|
Accuracy
|
Overload Protection
|
200mV
|
0.1mV
|
+-0.8% + 3
|
600V rms
|
2.00V
|
1mV
|
+-(0.8%
+ 1)
|
20.00V
|
10mV
|
200.0V
|
100mV
|
|
600V
|
1V
|
+-(1.0% + 3)
|
Remarks: Input impedance: 10MΩ
Resistance Auto
Range:
Range
|
Resolution
|
Accuracy
|
Overload
|
| 200.0Ω |
100mΩ |
+-(1.2% + 2)
|
600Vp
|
| 2.00kΩ |
1Ω |
+-(1% + 2)
|
| 20.00kΩ |
10Ω |
| 200.0kΩ |
100Ω |
| 2.00MΩ |
1kΩ |
+-(1.2% + 2)
|
| 20.00mΩ |
10kΩ |
+-(1.5% + 2)
|
Remarks: Input impedance: 10MΩ.
Continuity Test:
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
|
100mΩ |
Around 50Ω
buzzer beeps
|
600Vp
|
Remarks:
- Open circuit voltage approximate 0.45V
- The buzzer may or may not beep when the
resistance of a circuit under test in between 50Ω and 120Ω.
- The buzzer may not beep when the resistance of a
circuit under test is greater then 120Ω.
Diode
Test:
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
|
1mV
|
Display
approximate
forward voltage drop 0.5V-0.8V
|
600Vp
|
Temperature 225 x L only.
Range
|
Resolution
|
Accuracy
|
Overload
Protection
|
-40o-1000oC
|
1oC
|
-40-0o +- 3% + 4
|
600Vp
|
0-400oC +- 1% + 3
|
| 400-1000o +- 2% |
Accuracy (+-a% reading + b
digits)
Operating temperature 23oC +- 5oC
Relative Humidity: 75%
non-condensening
Temperature coefficient 0.1 x
(specified accuracy) / oC.
|