DCA - ACA True RMS World's smallest ACA/DCA Clamp Meter with Big Features No. 1 Versatility Developed by kaise Corp, Japan, 15 - Functions - in - ONE. 4000 counts Max. reading 4050, 12mm High, Voltage DC 400.0mV-600V AC 4.000V-600V, ACA/DCA 40.00 - 400.0A, Resistance, Continuity test, Diode test, Capacitance, Peak Hold (Mod: .36 Trms) Max/Min measurement (Mod: 32) Power - on Initialize (for DC Current Measurement) Display Hold, Auto Power off Saves Battery power, double moding rubber on Function switch and Trigger prevents fingers slip, Elegant compact design with wide range of measurement are possible in one easy to use Clamp offers high flexibility that can keep with any measurement demands.
Features:
- Mod: Matrix + 32 Average Rectification MAX / MIN measurements.
- Mod: Metrix + 36Trms True RMS Measurement.
- High-accuracy at + - 1.5%
- Compact size Clamp of Conductor Beaked shape Diameter 27mmØ.
- Max/Min. Peak Hold, Display hold, DIFF measurement
- Power-on Initialize (for DC Current measurements)
- Auto Power Off prevents battery consumption
- EMCD and LVD (IEC CE Mark is approved and passed 61010 - 1)
Display
|
4000 Count LCD Maximum reading 4050 12mm
|
Sampling Rate
|
3 times / sec.
|
Range Selection
|
Auto Ranging
|
Conductor Diameter
|
Max Ø27mm |
Power Supply
|
Two 1.5V R03 (or AAA) Batteries x 2 not attached
|
Dimension & Weight
|
170(H) x 58(W) x 27(D)mm, 160g battery included
|
Accessories
|
One pair of Test Leads, Instruction manual
|
DCA
|
40.00a
|
+- 1.5% rdg. + dgt
|
Max. Input Current 400AD
|
400.0a
|
40-200a/+-1.5%rdg+-5dgt 201-300a/+-3.0%rdg+-3dgt 301-400A/+-4.0%rdg+-3dgt
|
ACA
|
40.00A
|
+-1.5%rdg +-5dgt(50-60Hz)
|
Max. Input Current 400A rms
|
400.0A
|
40-200A/+-2.0%rdg+-3dgt(50-60Hz) 201-300A/+-4.0%rdg+-5dgt(50-60Hz) 301-400A/+-5.0%rdg+5dgt(50-60Hz)
|
Frequency (Hz)
|
5.00Hz - 1.000kHz
|
+- 0.2% rdg +- 2dgt
|
Max. Input Current 400Arms
|
Peak Current (Metrix+36Trms)
|
400.0A
|
+-0.2%rdg+5dgf
|
Max. Input Current 400A peak
|
DCV
|
400.0mV
|
+-1.0%rdg+-3dgt
|
Max. Input Current 800V DC
|
4.000/40.00/400.00/600V
|
+-1.0%rdg+2dgt
|
ACV
|
4.000/40.00/400.00/600V
|
+-1.5%+-5dgt (40-400Hz)
|
Max. Input Current 600V rms
|
Frequency (Hz)
|
5.00Hz-49.99 kHz
|
+-0.2%rdg+-3dgt
|
Max. Input current 600V rms
|
Duty Cycle (%)
|
5.0% - 95.0%
|
+-1.0%rdg+3dgt
|
Resistance (Ω) |
400.0Ω |
+-1.5%rdg+-5dgt
|
Open circuit Voltage - 0.44
|
| 4.000k/40.00k/400.0kΩ |
+-0.7%rdg+-3dgt
|
| 4.000MΩ |
+-1.2%rdg+-5dgt
|
| 40.00MΩ |
+-3.0%rdg+-5dgt
|
Continuity Test
|
400.0Ω |
+-1.5%rdg+5dgt
|
Buzzer sound: Approx 50Ω or less Open circuit Voltage - 0.44
|
Diode Test
|
0-1.5V
|
+-5.0%rdg+5dgt
|
Open circuit Voltage <1.7V
|
Capacitance
|
50.00n/500.0n/5.000µ 50.00µ/100.0µF |
+-5.0%rdg+-10dgt
|
Open circuit voltage 50.00nF - 1.25V 500.0nF - 100.0µF - 0.44V
|
Operating Principle
|
Operating Temperature 0oC-40oC, <80%RH
|
Accuracy at 23oC+-5oC <80%RH in non-condensing)
|
Overload Protection Current: 600Arms for 1 min (600) Voltage: 1000V rms for 1min. Resistance: 300V rms for 1min
|
Battery warning "BAT" symbol appears
|
Power Consumption Approx. 15mA
|
Dielectric Strength 3.7kV for 1 minute (Between input terminal & case)
|
Optional accessories 880line separator 940 alligator clips
|
|